What Is an EICR? How to Read the Report and Its Codes

On this pageWhat does EICR stand for, and what does the report tell you?What is the purpose of an EICR?Is an EICR an electrical safety certificate?Is an EICR a legal requirement?Who needs an EICR?How often is an EICR required?What does an EICR involve?How do you read an EICR?What do C1, C2, C3 and FI mean?What should you do if your EICR is unsatisfactory?What is the difference between an EICR and an Electrical Installation Certificate?Who can carry out an EICR?How do you arrange an EICR?What is an EICR? Common questions answeredSources
What is an EICR? An EICR, short for Electrical Installation Condition Report, is a report on the condition of the fixed wiring in a property. In practice it is a record of how the electrics stood on the day, not a repair. An electrician inspects and tests the installation, and the report gives an overall result of satisfactory or unsatisfactory.
Checks Sorted does not carry out inspections or issue certificates itself. We match your enquiry with a participating independent professional, where we can.

Key facts

  • An EICR reports on the condition of the fixed wiring, and plug-in appliances are not part of it.
  • The overall result is satisfactory or unsatisfactory, and only a C1 or C2 code makes it unsatisfactory.
  • Landlords need one by law, on a 5 year cycle for a rented home.
  • Electrical Safety First advises every 10 years for a home you own and live in.
  • The report records what the electrician could not check, as well as what they found.
What is an EICR: an electrician using a torch to inspect an open consumer unit in a hallway
An EICR is a report on the condition of the fixed wiring.

What does EICR stand for, and what does the report tell you?

EICR stands for Electrical Installation Condition Report, and the report tells you whether the fixed wiring is in a satisfactory or unsatisfactory condition for continued use. The electrical installation is the fixed wiring and equipment built into a building. Electrical Safety First says the report details any observed damage, deterioration, defects, dangerous conditions and non-compliances with the present-day safety standard that might give rise to danger. The electrician checks the installation against BS 7671, the UK standard also known as the IET Wiring Regulations. NICEIC says you may also hear it called fixed wire testing or periodic inspection and testing. The meaning is the same across the UK, but the rules on who needs one differ by nation.

What is the purpose of an EICR?

The purpose of an EICR is to find out whether the electrics are safe to keep using. Electrical Safety First says the checks reveal overloaded circuits or equipment, find shock risks and fire hazards, identify defective work and highlight any lack of earthing or bonding. It adds that all installations deteriorate with age and use, which is why the checks are repeated.

Is an EICR an electrical safety certificate?

No, an EICR is a report rather than a certificate, although many people call it an electrical safety certificate. GOV.UK describes it as a report from the person who inspected and tested the installation, explaining the outcome and any work required. NICEIC also calls it an electrical safety check. If someone asks for an EICR certificate, they mean this same report. Yes for landlords, under the rules of each nation. Electrical Safety First calls it a legal requirement across the whole of the UK for privately rented homes. Each nation has its own rules, which our guide on whether an EICR is a legal requirement sets out.

Who needs an EICR?

Private landlords in all four UK nations need one, and so do social landlords in England, Scotland and Wales. The table shows who needs one in each situation:
Situation Is an EICR needed? Official source
Private rented home, England Yes, inspected and tested at least every 5 years GOV.UK
Social rented home, England Yes, the 2020 regulations were extended to social landlords in 2025 GOV.UK
Private rented home, Scotland Yes, landlords should ensure an EICR is completed every 5 years under the Repairing Standard Scottish Government
Rented home, Wales Yes, tested every 5 years unless the last report sets a shorter interval Welsh Government
Social rented home, Scotland and Wales Yes, the legal requirement covers socially rented homes too Electrical Safety First
Private rented home, Northern Ireland Yes, inspected and tested at least every 5 years Department for Communities
A home you own and live in Not a landlord duty. The advice is every 10 years, or when the property is being prepared for letting Electrical Safety First
Buying or selling a home Advised before selling, or before buying a previously occupied property Electrical Safety First
Business premises The regulation sets no EICR interval, and systems must be maintained to prevent danger Electricity at Work Regulations 1989, regulation 4
GOV.UK also lists tenancies that are excluded from the England rules, such as long leases and student halls of residence.

How often is an EICR required?

How often is an EICR required: a 5 year calendar beside a rented home and a 10 year calendar beside an owner-occupied home
A rented home needs an EICR at least every 5 years, and 10 years is the advice for a home you own.
A rented home needs one at least every 5 years, and Electrical Safety First advises every 10 years for a home you own and live in. The report itself sets the date of the next inspection and test, says GOV.UK, and our guide on how long an EICR lasts covers the timing in full. In Northern Ireland the qualified person can set a shorter interval if they think it is necessary, says the Department for Communities.

What does an EICR involve?

An EICR involves an electrician inspecting and testing the fixed electrical installation, then reporting on its condition. It covers the consumer unit, light fittings, light switches, socket outlets and any visible wiring, says the Scottish Government. Electrical Safety First lists what the inspection checks:
  • the adequacy of earthing and bonding
  • the suitability of the switchgear and controlgear
  • the serviceability of switches, sockets and lighting fittings
  • the type and condition of the wiring system
  • the protection of sockets that may supply outdoor equipment by a residual current device
  • the presence of adequate identification and notices

What checks and tests does the electrician carry out?

The electrician starts with a visual inspection and then tests the circuits, says NICEIC. The visual inspection looks for cracked sockets or switches, signs of overheating, damaged consumer units, missing covers, incorrect labelling and DIY alterations that may not meet BS 7671. The tests cover continuity, insulation resistance, polarity, earth fault loop impedance and RCD operation, and our guide on how long an EICR takes explains what affects the time.

Does an EICR check plug-in appliances?

No, an EICR covers the fixed installation, while plug-in appliances are checked separately by PAT testing. NICEIC says portable items you plug into socket outlets, such as hairdryers, fridges and TVs, are generally not part of the electrical installation. The Scottish Government guidance lists PAT testing as a separate check.

How do you read an EICR?

Read an EICR by finding four parts: the overall result, the next inspection date, the limitations and the observation codes. The IET model form for BS 7671 puts them in Sections E, F, D and K, and your report may be laid out differently. The codes have their own section below.

Where do you find the overall result and next inspection date?

The overall result is in Section E and the next inspection date is in Section F of the IET model form. Section E states whether the installation is satisfactory or unsatisfactory for continued service. Section F gives a date before which the installation should be inspected and tested again, with the reasons for it.

Where does the report show what the electrician could not check?

Section D of the IET model form records the extent of the inspection and any limitations, with the reasons. The extent should be agreed before the inspection starts. Unless agreed otherwise, the form says cables concealed in trunking, conduit, under floors, in roof spaces and within the fabric of the building have not been inspected. Operational limitations, such as being unable to gain access to part of the installation, are also recorded in Section D. If the inspector finds an issue they cannot verify because of those limits, it goes in Section K as FI, which means further investigation.

What do C1, C2, C3 and FI mean?

C1 means danger present, C2 potentially dangerous, C3 improvement recommended and FI further investigation required without delay, according to GOV.UK. The table shows what each does to the overall result:
Code What it means Effect on the overall result
C1 Danger present. Risk of injury. The report is unsatisfactory
C2 Potentially dangerous. The report is unsatisfactory
C3 Improvement recommended. Advisory, so it does not change the result
FI Further investigation required without delay. Advisory, so it does not change the result, but the investigation must be carried out
The IET model form says C3 and FI observations are advisory but should be given due consideration.

What should you do if your EICR is unsatisfactory?

Three steps after an unsatisfactory EICR: check the report codes, fix or investigate, then keep the paperwork
After an unsatisfactory EICR: check the report, fix or investigate, and keep the paperwork.
Have the C1 and C2 problems fixed, because an unsatisfactory report means the installation is not safe for continued use until they are. GOV.UK says that if code C1 or C2 is identified, remedial work is required. In England the landlord must complete the remedial or further investigative work within 28 days, or any shorter period the report gives.

How do you find out what needs repair or further investigation?

Look at the observations in Section K, because each one carries a code and a description of the problem. The IET model form says C1 items are to be made safe on discovery wherever practicable. Where that is not possible, the owner or user is to be given written notification as a matter of urgency.

What paperwork should you keep after the work is complete?

Keep the report and the written confirmation that the work is finished. GOV.UK lists a satisfactory EICR, an Electrical Installation Certificate, a Minor Electrical Installation Works Certificate or other appropriate electrical certification as acceptable written confirmation. A landlord in England must keep a copy of the report until the next inspection is due, unless a more recent report replaces it.

What is the difference between an EICR and an Electrical Installation Certificate?

An EICR reports on the condition of an existing installation, while an Electrical Installation Certificate (EIC) is issued for new work. According to GOV.UK, premises that are newly built or have been completely rewired should have an EIC. The two differ as follows:
EICR EIC
Full name Electrical Installation Condition Report Electrical Installation Certificate
What it is for Reporting on the condition of an existing installation New work, such as a newly built home or a complete rewire
What it means for a landlord in England The report the landlord must obtain, usually an EICR No further checks or report needed for 5 years after it is issued, if the landlord has met their duties

Who can carry out an EICR?

A competent person, such as a registered electrician, can carry out an EICR. Electrical Safety First says periodic inspection and testing should be carried out only by electrically competent persons. GOV.UK calls this a qualified person, meaning someone competent to inspect and test the installation. Landlords can use the Registered Competent Person Electrical register or the Electrical Safety First register of electricians, which GOV.UK points them to.

How do you arrange an EICR?

Send Checks Sorted one enquiry for an EICR and we match it with a participating independent professional covering your area, where we can. We do not visit or test properties ourselves. It takes four steps:
  1. Choose the EICR Select it from the list of services.
  2. Enter the postcode Add the property postcode and a few basics.
  3. Receive a match We find a participating professional who covers the service and your area.
  4. Settle the details They contact you about availability, price and the work.

Get an EICR quote

What is an EICR? Common questions answered

How much does an EICR cost in the UK?The price depends on the property and the work involved, so it comes from the professional who quotes. Checks Sorted does not set prices. Our EICR cost guide explains what affects the price and what to ask in a quote.
Is an EICR the same as PAT testing?No, they are different checks. An EICR covers the fixed installation, while PAT testing checks portable electrical appliances, as the plug-in appliances section above explains. The Scottish Government guidance lists the two as separate parts of an electrical safety inspection.
What fails an EICR?Nothing passes or fails, because an EICR is a report on condition. Only a C1 or C2 makes the report unsatisfactory, says GOV.UK, while C3 and FI observations are advisory and do not change the result.
Does an EICR cover solar panels or battery storage?Not necessarily, because these specialist systems may need a separate inspection by an appropriately qualified person, says GOV.UK. That inspection is in addition to the EICR requirements for rented homes.
Can an EICR cover only part of a property?The extent of the installation covered is identified in the report and agreed before the inspection, says the IET model form. For a rented home, GOV.UK requires the electrical installations in the property to be inspected and tested.
Is there an EICR checklist?Yes, the Schedule of Inspection in the IET model form works as the checklist. It lists the items the inspector checks, gives each one an outcome, and can be reduced or expanded to suit the installation.

Sources